Aerospace NESHAP Filtration
Aerospace NESHAP requires the use of high efficiency filters to remove 95% removal of particulates over 2 micron size. The use of a 3-stage filtration system is mandated and the filters must be certified in accordance with EPA Method 319.
GFS uses a filtration system that provides 99% removal of most paint spray aerosols. This makes the approval of these booths by environmental agencies a simple matter.
NESHAP filtration also requires operation of the filter chamber at very negative static pressures. We typically operate at 3” static pressure. This means exhaust chambers must be structurally stiffened to withstand these pressures.
|