Select Downdraft:
High-Performance airflow design
*Floor exhaust pit required
Downdraft airflow provides the optimum airflow for overspray removal. Air is drawn through the ceiling filters, over the vehicle, and is exhausted through a pit in the floor. All overspray is safely contained in the pit filters.
Cabin Specifications:
Non-Pressurized:
Internal: 26'l x 14'w x 9'h
External: 26'4"l x 14'4"w x 9'2"h
2-Wing Frontal: 10'w x 9'h
Pressurized:
Internal: 26'l x 14'w x 9'h
External: 26'4"l x 14'4"w x 11'4"h
2-Wing Frontal: 10'w x 9'h
Construction:
-Downdraft airflow during spray and cure cycles
-Single-row exhaust pit (21'4" long)
-G-90 galvanized steel
Doors:
-10'w x 9"h 2-wing entrance door (10'w x 8'10"h opening)
-1 Personnel access door
Lighting
-ETL-Listed inside-accessible light fixtures 102/277v
-(10) 4-tube light fixtures
-Energy-efficient electronic ballasts
-T-8 Color-corrected fluorescent tubes
Exhaust System:
-(1) 34" Tube-axial Fan
-(1) 5hp EPACT Motor
-12,600 CFM @ 3/4" SP
-Booth pressure manometer gauge
Filtration:
-High-efficiency, high-temperature compatible ceiling filter media
-high holding capacity filter media in pit
White pre-coated panels are optional |